December 3, 2024
94Passed20 findings · 6 points deducted
Points deducted (100 − 6 = 94):
- −2 ptsItem 10: RWF maintenance, safety equipment
- −2 ptsItem 44: Person in charge; Knowledge
- −1 ptItem 08: PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained
- −1 ptItem 33: Decks / bulkheads / deckheads construction, repair, clean
All 20 findings the inspectors wrote down, grouped by area of the ship. Findings with a red edge belong to an item that lost points; the others were noted without a deduction.
Drinking water5 findings
- Item 05Deck 2 - Lower Far Point
The manual test kit measured greater than 0.2 ppm compared to the analyzer. The analyzer indicated 1.39 - 1.41 ppm. The inspector measured 1.77 and 1.72 ppm.
- Item 05Deck 7 - Upper Far Point
The manual test kit measured greater than 0.2 ppm compared to the analyzer. The analyzer indicated 1.18 - 1.19 ppm. The inspector measured 1.72 and 1.81 ppm. The crew measured 0.77, 1.42, and 1.43 ppm.
- Item 08Engine Room - Forward Diesel Generator Room
The distillate water line from aft evaporator #2 was striped both blue/brown/blue and blue 'potable water' before the reduced pressure principle assembly. Staff explained this line is for technical water only.
- Item 08Garbage Room
Two atmospheric vacuum breakers and three vented double check valve assemblies were installed on the potable water lines to the biodigesters, however, these were not on the cross-connection control log. This was written on the March 2023 inspection report.
- Item 44Test Kit
The onboard water test kit used to sample potable water and recreational water facilities continuously measured halogen and pH values greater than 0.2 ppm chlorine and 0.2 pH when compared to the respected analyzers. This was observed at the Deck 2 Lower Far Point analyzer, Deck 7 Upper Far Point analyzer, Aft and Forward Starboard Whirlpool Spa analyzers, and the Aft Pool analyzer.
Pools, hot tubs and water play areas2 findings
- Item 10Aft and Forward Starboard Whirlpool Spa Analyzers
Manual pH comparison tests of the aft starboard whirlpool spa analyzer measured a difference greater than 0.2 ppm. The analyzer indicated pH 6.89. Manual pH comparison test to the analyzer by the inspector measured less than 6.5. Manual pH comparison test by the crew measured greater than 8.1. Manual chlorine comparison tests of the forward starboard whirlpool spa analyzer measured greater than 0.2 ppm. The analyzer indicated 4.31 ppm chlorine. Manual chlorine comparison test to the analyzer by the inspector twice measured greater than 10.0 ppm. Manual chlorine comparison test by the crew measured 5.25, 5.6, 5.23, and 5.21 ppm.
- Item 10Aft Pool Analyzer
Manual chlorine comparison tests of the analyzer measured greater than 0.2 ppm. The analyzer indicated 2.6 ppm chlorine. Manual chlorine comparison test to the analyzer by the inspector measured 8.74 ppm. Manual chlorine comparison test by the crew measured 3.23 ppm. Manual pH comparison tests of the analyzer measured greater than 0.2. The analyzer indicated pH 7.36. Manual pH comparison test to the analyzer by the inspector measured pH 7.74. Manual pH comparison test by the crew measured pH 7.8, 7.6, and 7.6.
Food safety, general1 finding
- Item 33Decks and Deckheads
The deck tiles and grout were in disrepair in the following areas: (1) deck 11 - Surf & Turf; (2) deck 9 - bar pantries, Islands Galley and dishwashing area; (3) decks 4 and 5 - main galleys, and (4) deck 2 - crew galley. Water dripped from the deckhead in the vegetable refrigerator. Additionally, ice accumulated on the deckhead in the following areas: (1) butcher walk-in refrigerator; (2) fish freezer around the fire sprinkler; and (3) frozen vegetables refrigerator. No food was impacted.
Buffets4 findings
- Item 29Deck 9 - Islands Buffet Starboard Side Hot Line
When the inspector was in the area, the handwashing station was not functioning. The crew stated the workers will either use the handwashing station on the portside hot line, omelet station, or in the galley behind a closed door. The inspector and crew discussed that using the handwashing station behind the closed door is not acceptable and that the crew should be directed to use the other two handwashing stations. The handwashing station was fixed before the end of the inspection.
- Item 36Deck 9 - Islands Buffet Carving Station
The protective coating was missing on the far-left heat lamp bulb.
- Item 39Deck 9 - Islands Buffet Starboard Side Beverage Station
Two flies were inside the technical space under the beer dispensers.
- Item 39Deck 9 - Islands Buffet Portside Deli Station
A small fly was in the area.
Galleys (kitchens)3 findings
- Item 21Deck 4 - Sauce Station
The technical space cover behind the grooved grill was in disrepair which created a difficult to clean area.
- Item 27Deck 5 - Italian Galley
A small amount of grease residue was on the previously cleaned exhaust hood overhang for the hot plate cooking area. This was re-cleaned immediately.
- Item 39Deck 5 - Gallery 47 Room Service
A small fly was near the coffee station.
Bars2 findings
- Item 19Deck 6 - The Coffee Port
The dipper well was not protected from possible contamination from passengers who could stand less than one meter away.
- Item 39Deck 4 - Live Room
A small fly was around the handwashing station in the corner.
Other areas1 finding
- Item 21Deck 9 - Spa Beverage Station
The sealant at the countertop/bulkhead juncture was in disrepair which created seams along the edge. This was corrected immediately.
Food preparation rooms1 finding
- Item 39Deck 1
A small fly was around the potato peeler.
Food storage (provisions)1 finding
- Item 36Deck 1 - Breakfast Thawing
The light intensity measured less than 110 lux in the corner opposite the condenser.