June 17, 2026
88Passed74 findings · 12 points deducted
Points deducted (100 − 12 = 88):
- −3 ptsItem 26: Food-contact surfaces equipment / utensils clean; Safe
- −2 ptsItem 19: Food protected storage, preparation, display, service, transportation; Original containers, labeling; Food handling minimized; In-use food dispensing, preparation utensils stored
- −2 ptsItem 28: Equipment / utensil / linen / single / service storage, handling, dispensed; Clean frequency
- −2 ptsItem 44: Person in charge; Knowledge
- −1 ptItem 08: PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained
- −1 ptItem 33: Decks / bulkheads / deckheads construction, repair, clean
- −1 ptItem 37: Rooms / equipment vented, humidity, condensation
All 74 findings the inspectors wrote down, grouped by area of the ship. Findings with a red edge belong to an item that lost points; the others were noted without a deduction.
Galleys (kitchens)40 findings
- Item 12Deck 1 - Galley
The technician wore gloves to remove the screws and open the cover of the ice machine; he then proceeded to use the same gloves (and without washing his hands) to open the plastic evaporator panel.
- Item 19Deck 2 - Soup and Sauce Station
Condensate continuously dripped from the deckhead ventilation hood directly above the soup and sauce kettles and landed on top of the deck and the kettle lids. Condensate also dripped from deckhead light fixtures and the sprinkler system beside the hood. Soup and sauces were being cooked in the kettles at the time of the inspection. It was unclear how the food could be transported from the kettles without water dripping into it.
- Item 20Deck 7 - Kings Court Forward
Water/grease leaked from the top stacked combination oven front door onto the unit below and on the deck near the grooved grill.
- Item 20Deck 7 - Kings Court
The blast chiller in the area has been out of service since January 2026.
- Item 20Deck 7 - Piazza
The blast chiller in the area has been out of service since March 2026.
- Item 20Deck 7 - Grills
The blast chiller in the area has been out of service since December 2024. The crew are using another blast chiller so it does not impede operations.
- Item 20Deck 7 - Grills Pastry Freezer
The walk-in freezer was out of service since 15 June 2026. No food was stored in the freezer.
- Item 20Deck 2 - Production
One oven had been out of service since 13 June 2026.
- Item 21Deck 1 - Freezer
A thick layer of frozen condensate collected on the evaporative condenser unit, deckhead, bulkheads, and shelves.
- Item 21Deck 10 - Room Service
The combination oven drain was clogged causing water to drip onto the countertop below. This was cleaned immediately.
- Item 21Deck 2 - Storage Locker #29.3
A damaged and soiled blender was stored on a shelf among new food equipment.
- Item 21Deck 7 - Piazza
Water dripped into the scupper drain from the technical compartment of the right soup kettle.
- Item 22Deck 7 - Kings Court Forward Dishwash
Water dripped from the bottom left of the hood-type dishwash machine.
- Item 22Deck 7 - Kings Court Scullery
The bottom final sanitizing spray nozzles on both sides of the machine were observed to be blocked. Corrective action was initiated immediately during the inspection.
- Item 22Deck 1 - Scullery
Utensils were improperly racked on top of each other in a tray exiting the flight-type warewash machine.
- Item 24Deck 7 - Piazza
The sanitizer bucket measured above 200 ppm. This was changed immediately.
- Item 26Deck 2 - Brittania
Water pooled in the bottom of undercounter refrigerator #2; no food was stored inside.
- Item 27Deck 1 - Dish Storage
One stack of previously cleaned and sanitized bowls (8 in total) were stacked wet nested causing water to accumulate on the storage shelf.
- Item 27Deck 7 - Kings Court Forward
Water/grease leaked from the top stacked combination oven front door onto the unit below and on the deck near the grooved grill.
- Item 27Deck 2 - Soup and Sauce Station
Condensate continuously dripped from the deckhead ventilation hood directly above the soup and sauce kettles and landed on top of the deck and the kettle lids. Condensate also dripped from deckhead light fixtures and the sprinkler system. Crew stated the issue first occurred in March 2026 and was determined to come from an inadequately insulated brine line. It was unclear when the technical team planned to resolve the issue.
- Item 27Deck 2 - Storage Locker #29.3
A damaged and soiled blender was stored on a shelf among new food equipment.
- Item 27Deck 2 - Garde Manger
Condensate collected on the sides and top of undercounter storage cabinets. This appeared to be due to the refrigerator unit on the other side of the cabinets. No dishes were stored inside the cabinets.
- Item 28Deck 2 - Storage Locker #29.3
A damaged and soiled blender was stored on a shelf among new food equipment.
- Item 28Deck 1 - Dish Storage
One stack of previously cleaned and sanitized bowls (eight in total) were stacked wet nested causing water to accumulate on the storage shelf.
- Item 33Deck 1 - Freezer
A thick layer of frozen condensate collected on the evaporative condenser unit, deckhead, bulkheads, and shelves.
- Item 33Deck 1 - Combination Ovens
Excessive condensate collected in the exhaust hood above the two combination ovens and dripped onto the deck.
- Item 33Deck 1 - Crew Bar
Excessive water accumulated on the deck around the perimeter of the bar working area. It was unclear where the water had come from since the bar was last used and cleaned the night before the inspection.
- Item 33Deck 7 - Kings Court Cold Room #3
An open seam was around the deckhead hatch inside the walk-in.
- Item 33Deck 7 - Kings Court Forward
A seam was around a deckhead hatch over a preparation area. Additionally, a seam was at the deckhead profile strip to the right of the handwashing station near the entrance.
- Item 33Deck 7 - Piazza
Water dripped from the outside of the deckhead/exhaust hood overhang juncture near the combination ovens. The source could not be identified and the water did not pool on the deck.
- Item 33Deck 2 - Soup and Sauce Station
Condensate continuously dripped from the deckhead ventilation hood directly above the soup and sauce kettles and landed on top of the deck and the kettle lids. Condensate also dripped from deckhead light fixtures and the sprinkler system. Crew stated the issue first occurred in March 2026 and was determined to come from an inadequately insulated brine line. It was unclear when the technical team planned to resolve the issue.
- Item 33Deck 7 - Grills
The deck grout was missing or recessed in small areas throughout the galley.
- Item 33Deck 7 - Grills Pastry Cold Room
Water dripped from the deckhead hatch. No food was impacted.
- Item 33Deck 10 - Room Service
The deck grout was recessed in front of the potwash area.
- Item 33Deck 7 - Kings Court Forward
Water/grease leaked from the top stacked combination oven front door onto the deck near the grooved grill.
- Item 33Deck 7 - Kings Court Forward Dishwash
Water pooled on the deck from the bottom left of the hood-type dishwash machine.
- Item 33Deck 12 - Boardwalk Cafe
Water consistently dripped from the deckhead and along the exit sign and pooled on the deck near the clean storage rack. The area was not in operation. The source of the water could not be identified.
- Item 37Deck 7 - Grills
Condensate collected on the supply vent above soiled side of the 3-compartment sink. Water did not drip and the area was not in operation.
- Item 37Deck 2 - Soup and Sauce Station
Condensate continuously dripped from the deckhead ventilation hood directly above the soup and sauce kettles and landed on top of the deck and the kettle lids. Condensate also dripped from deckhead light fixtures and the sprinkler system. Crew stated the issue first occurred in March 2026 and was determined to come from an inadequately insulated brine line. It was unclear when the technical team planned to resolve the issue.
- Item 37Deck 1 - Combination Ovens
Excessive condensate collected in the exhaust hood above the two combination ovens and dripped onto the deck.
Pantries11 findings
- Item 08Deck 12 - Boardwalk Cafe
Brown debris was obstructing the atmospheric air vents of the backflow prevention device for the coffee machine.
- Item 20Deck 8 - Corinthia Bar
The soda gun had a slotted fastener on the food contact side.
- Item 20Deck 6 - Pantry # 2
The ice scoop holder inside the ice bin protruded from the side of the bin, creating a ledge that was difficult to clean.
- Item 21Deck 8 - Corinthia Bar
Water dripped from the underside of the ice machine and pooled on the deck below.
- Item 22Deck 4 - Pantry # 2
The undercounter dishwash machine was out of service since the morning.
- Item 26Deck 8 - Corinthia Bar
An excessive amount of black debris was on the outside and inside of the food contact area of the evaporator panel. The machine was take out of service to be cleaned and sanitized.
- Item 26Deck 4 - Pantry # 2
Excessive accumulation of black moldy deposits were on the internal side of the plastic evaporator ice deflector panel. Black residue was also on the internal hard to reach corners in the technical compartment and on the evaporator side of the ice thickness sensor.
- Item 27Deck 6 - Pantry # 2
A soiled container holding used glasses and soiled linen was stored on the clean counter adjacent to a container of cleaned and sanitized glasses. Coffee residue from the used glasses had spilled onto the clean countertop.
- Item 28Deck 6 - Pantry # 2
A soiled container holding used glasses and soiled linen was stored on the clean counter adjacent to a container of cleaned and sanitized glasses. Coffee residue from the used glasses had spilled onto the clean countertop.
- Item 33Deck 12 - Pavilion Cold Room
Water dripped form the deckhead hatch onto the deck below.
- Item 33Deck 8 - Corinthia Bar
Water dripped from the underside of the ice machine and pooled on the deck below.
Food storage (provisions)6 findings
- Item 19Deck A - Fruit
Wet cardboard boxes containing bags of thawing pasteurized liquid eggs were stored on a pallet.
- Item 19Deck B - Corridor
Twelve cases of bottled water were stored on a wooden pallet. Crew stated the water was provisioned in South Hampton.
- Item 33Deck A - Vegetable
Condensate dripped from the deckhead seams and landed on the deck. Crew stated this due to a inadequate insulation surrounding refrigeration pipes and was scheduled to be fixed during the scheduled 2027 dry dock.
- Item 33Deck A - Fruit
Condensate continuously dripped from a deckhead light fixture.
- Item 33Deck A - Fruit
A substance pooled on the deck beneath a pallet of thawing pasteurized liquid eggs.
- Item 37Deck A - Vegetable
Condensate continuously dripped from the deckhead seams and landed on the deck. Crew stated this due to a inadequate insulation surrounding refrigeration pipes and was scheduled to be fixed during the scheduled 2027 dry dock.
Housekeeping6 findings
- Item 19Deck 5 - Chemical Pantry
Food equipment and food items were stored in a pantry where chemical disinfectant was dispensed. Clean champagne flutes, drinking glasses, ice buckets, and bottled water were stored on a cabinet shelf alongside a bottle of carpet spot remover. The cabinet also contained cleaning supplies, soaps, and other non-food-related items. In addition, boxed champagne bottles were stored directly on the deck. The pantry had an open deckhead with exposed cables and ductwork.
- Item 19Turnaround Process
Boxes of champagne were observed stored directly on the deck on multiple decks during delivery to the staterooms.
- Item 28Deck 5 - Staterooms
During the turnaround process, cleaned and sanitized champagne flutes in at least four staterooms were observed lying on their sides on luggage mats that had been placed over the beds. When questioned, the stateroom steward stated that the glasses were temporarily placed on the luggage mats while the countertops were being dusted and would be returned to the countertops for use by the next passengers.
- Item 28Deck 5 - Chemical Pantry
Food equipment and food items were stored in a pantry where chemical disinfectant was dispensed. Clean champagne flutes, drinking glasses, ice buckets, and bottled water were stored on a cabinet shelf alongside a bottle of carpet spot remover. The cabinet also contained cleaning supplies, soaps, and other non-food-related items. In addition, boxed champagne bottles were stored directly on the deck. The pantry had an open deckhead with exposed cables and ductwork.
- Item 41AGE Stateroom Cleaning and Disinfecting Log
Daily stateroom cleaning and disinfection of an AGE passenger case on voyage 611R, did not have a record for 8 June. The log indicated the cleaning took place on the initial isolation day (7 June) and the day the passenger was released from isolation on 9 June. Staff stated this was conducted, though not recorded in the log.
- Item 41Deck 5 - Chemical Pantry
The chemical test strip indicated zero chemical concentration when the disinfectant solution in the pantry was tested. The chemical concentrate container supplying the dispenser was found empty.
Buffets3 findings
- Item 08Deck 7 - Kings Court Beverage Station - Forward Portside
The majority of the atmospheric air vents on the backflow prevention devices were observed to be blocked or obstructed, which could prevent the devices from functioning as designed.
- Item 19Deck 1 - Service Line
A serving tong was laying inside the tray and directly on top of hot dogs.
- Item 39Deck 7 - Piazza Waiter Station
One small fly was in the area.
Drinking water2 findings
- Item 08Reduced Pressure Zone (RPZ) Assemblies
Two RPZ backflow prevention devices that failed their most recent pressure tests on 26 September 2025 remained in place and had not been repaired or replaced. These included the RPZs serving the distillate filling connection and the foam injector. Water was observed continuously leaking from the relief vent and top of the distillate filling RPZ. Staff stated that replacement parts for this RPZ had arrived, but repairs had not yet been completed.
- Item 08Engine Room - Pipe Striping
Sections of piping were not properly labeled as potable water (blue or blue/green/blue) in areas of the engine room. Additionally, sections of piping for technical purposes were striped blue/gray/blue but was not directed to potable water production.
Pools, hot tubs and water play areas3 findings
- Item 10Flow Rates
Flow rates for multiple recreational water facilities did not meet the minimum required flow rates necessary to achieve the required turnover rates. These included the two whirlpools on Deck 2, with an observed flow rate of 12 m³/h compared with the required 16 m³/h, and the Hydropool, with an observed flow rate of 20.7 m³/h compared with the required 26.6 m³/h.
- Item 10Hydropool Safety Sign
The depth marker was positioned on the wall above the entrance to the locker room and was not easily seen from the deck and pool.
- Item 44Water Testing / Children's Pool
During residual testing of the Hydropool, the pool technician used a high-range test reagent but selected the low-range test setting on the photometer. Additionally, the light intrusion gasket was not used on the sample vial, and the photometer chamber was heavily soiled with black residue, which was removed with a cloth during the inspection. Staff also stated that the splash pool was not being maintained at the required halogen residual of 2–5 ppm for a children’s pool. The company’s website identifies the facility is dedicated for children, the pool is less than 1 meter deep, and posted signage advises frequent toilet breaks for children. The splash pool was not in operation on the day of the inspection. In addition, three of the four recreational water facilities examined did not have flow rates sufficient to meet the required turnover rates.
Food safety, general2 findings
- Item 21Biodigesters
Crew stated eight biodigesters located throughout food service areas were out of service on the day of the inspection.
- Item 39Pests
Flies were seen in the following food areas: - 1 fly near the Garde Manger storage cabinets - 1 fly in the Golden Lion Pub Pantry - 1 fly in the Chart Room Pantry - 1 fly in the Crew Mess Beverage Line
Food preparation rooms1 finding
- Item 30Deck 1 - Buffet
The door for the crew's toilet room was not self-closing.