December 14, 2025
92Passed51 findings · 8 points deducted
Points deducted (100 − 8 = 92):
- −3 ptsItem 09: RWF halogen residuals
- −2 ptsItem 10: RWF maintenance, safety equipment
- −1 ptItem 21: Nonfood-contact surfaces designed, constructed, maintained, installed, located
- −1 ptItem 33: Decks / bulkheads / deckheads construction, repair, clean
- −1 ptItem 37: Rooms / equipment vented, humidity, condensation
All 51 findings the inspectors wrote down, grouped by area of the ship. Findings with a red edge belong to an item that lost points; the others were noted without a deduction.
Galleys (kitchens)26 findings
- Item 08Deck 4 - Beverage Station
A potable water line to the ice machine was incorrectly marked blue/white/blue.
- Item 12Deck - 9 Colonnade - Show Galley
A crew member touched raw egg with his gloved hands while wiping the inside of an actively cooking pan and proceeded to continue working at the station cooking omelets. Without removing gloves, the crew member subsequently handled a cooking pan and passed it to another crew member who also touched the same handle as he plated the omelet. This crew member then touched the service plate with the same hand.
- Item 16Deck 4 - Cold Galley
A container of egg salad was marked with a discard date from the date of preparation (Dec 12th) and not from the date the eggs were cooked (Dec 10th).
- Item 18Deck - 9 Colonnade - Show Galley
A crew member touched raw egg with his gloved hands while wiping the inside of an actively cooking pan and proceeded to continue working at the station cooking omelets. Without removing gloves, the crew member subsequently handled a cooking pan and passed it to another crew member who also touched the same handle as he plated the omelet. This crew member then touched the service plate with the same hand.
- Item 20Deck 4 - Beverage Station
Open penetrations were in the underside plastic housing above the dispensing nozzles of the water dispenser.
- Item 20Deck 8 - Solis
Open penetrations were in the underside plastic housing above the dispensing nozzles of the water dispenser.
- Item 21Deck 8 - Solis
The electrical cable for the warming cabinet and the espresso drain lines were draped on the counter.
- Item 21Deck 4 - Beverage Station
Electrical cables were draped on the counter.
- Item 21Deck - 9 Colonnade - Show Galley
The electric cable for the microwave was draped on the countertop, impeding proper cleaning.
- Item 21Deck - 9 Colonnade
The electric cable for the conveyor toaster was draped on the countertop, impeding proper cleaning.
- Item 21Deck - 9 Patio Grill
Varnished wood was throughout this show galley at the service stations deckheads and bulkheads. This material was sticky and in poor repair. Several areas including near the handwashing sink the varnish had worn away and was mostly raw untreated wood. Additionally, the undercounter refrigerator doors panels were made from this material and were in bad condition.
- Item 21Deck - 9 Patio Grill
Three mounted refrigerators were installed along the bulkhead at the galley entryway, an area not constructed for food storage. The installation lacked proper deck/bulkhead coving, adequate lighting, and contained open penetrations in the deckhead where electrical wiring passed through. Additionally, the units were positioned too closely together to allow for effective cleaning between and behind them. The deck and bulkhead surfaces beneath and behind the units were soiled. The refrigerators were mounted on metal posts approximately 5 inches off the deck and could not be easily moved for cleaning.
- Item 22Deck - 9 Colonnade - Dishwash
A piece of clear plastic blocked one of the wash nozzles of the glasswash machine.
- Item 25Deck - 9 Colonnade - Dishwash
A wiping cloth was not fully submerged in a bucket of sanitizing solution.
- Item 27Deck - 9 Patio Grill
Varnished wood was throughout this show galley at the service stations deckheads and bulkheads. This material was sticky and in poor repair. Several areas including near the handwashing sink the varnish had worn away and was mostly raw untreated wood. Additionally, the undercounter refrigerator doors panels were made from this material and were in bad condition.
- Item 27Deck - 9 Colonnade Hot Galley
Stagnant white liquid residue pooled in the underside black catch reservoir of the counter mounted combination oven furthest from the dishwashing machine. Additionally, dried and greasy residue was on the underside of the combination oven nearest the dishwashing machine.
- Item 30Deck - 9 Colonnade
The right hand towel dispenser was out of towels at the soiled dish drop off handwash station.
- Item 33Deck - 9 Patio Grill
Three mounted refrigerators were installed along the bulkhead at the galley entryway, an area not constructed for food storage. The installation lacked proper deck/bulkhead coving, adequate lighting, and contained open penetrations in the deckhead where electrical wiring passed through. Additionally, the units were positioned too closely together to allow for effective cleaning between and behind. The deck and bulkhead surfaces beneath and behind the units were soiled. The refrigerators were mounted on metal posts approximately 5 inches off the deck and could not be easily moved for cleaning.
- Item 33Deck - 9 Patio Grill
Deck coving at the preparation counter and deck juncture was in poor repair.
- Item 33Deck - 9 Patio Grill
Varnished wood was used throughout the show galley at the service stations, deckheads, and bulkheads. This material was sticky and in poor repair. In several areas, including near the handwashing sink, the varnish had worn away, leaving exposed, untreated wood. Additionally, the undercounter refrigerator door panels were constructed of the same material and were in poor condition.
- Item 33Deck - 9 Colonnade - Dishwash
Condensate collected on the deckhead throughout this area and in some locations it was dripping to the deck. Condensate was most evident on the cold air returns and deckheads near the soiled and clean side of the active flight-type dishwasher. Water was also dripping from a deckhead speaker onto the deck.
- Item 33Deck 4 - Pastry
Water lines to the gelato machine were on the deck and in standing water. Additionally, the bulkhead in back was soiled with apparent flour residue.
- Item 36Deck 3
Light intensity on the preparation counter with the deli slicer could not reach 220 lux.
- Item 36Deck - 9 Patio Grill
Three mounted refrigerators were installed along the bulkhead at the galley entryway, an area not constructed for food storage. The installation lacked proper deck/bulkhead coving, adequate lighting, and contained open penetrations in the deckhead where electrical wiring passed through. Additionally, the units were positioned too closely together to allow for effective cleaning between and behind them. The deck and bulkhead surfaces beneath and behind the units were soiled. The refrigerators were mounted on metal posts approximately 5 inches off the deck and could not be easily moved for cleaning.
- Item 37Deck - 9 Colonnade - Dishwash
Condensate collected on the deckhead throughout this area and in some locations it was dripping to the deck. Condensate was most evident on the cold air returns and deckheads near the soiled and clean side of the active flight-type dishwasher. Water was also dripping from a deckhead speaker onto the deck.
- Item 38Deck 4 - Cold Galley
Staff reported the vegetable chopper is no longer used.
Food storage (provisions)4 findings
- Item 19Meat Freezer
Ice accumulated on top of boxes of pork products below the condenser unit at the back of the room.
- Item 33Corridors
Water was dripping from the deckhead, a deckhead speaker, and adjacent hatches. Staff reported that this was due to high humidity and inadequately insulated cold-water lines within the deckhead. Water accumulated on the deck in several areas.
- Item 33Dry Store
Standing water was on the deck underneath the condenser near the back of the room.
- Item 37Corridors
Water dripped from the deckhead, a deckhead speaker, and adjacent hatches. Staff reported this was due to high humidity and poorly wrapped cold water lines in the deckhead. Water accumulated on the deck in areas.
Dining rooms3 findings
- Item 21Deck 4 - Beverage Storage - Galley Entrance
Refrigerators were installed along the bulkhead near the galley entrance on both the port and starboard sides. These units did not have adequate lighting and did not allow for proper cleaning behind or between them. The deck and bulkhead surfaces beneath and behind the units were soiled. The refrigerators were mounted on metal posts approximately five inches above the deck and could not be easily moved to facilitate cleaning.
- Item 33Deck 4 - Beverage Storage - Galley Entrance
Refrigerators were installed along the bulkhead near the galley entrance on both the port and starboard sides. These units did not have adequate lighting and did not allow for proper cleaning behind or between them. The deck and bulkhead surfaces beneath and behind the units were soiled. The refrigerators were mounted on metal posts approximately five inches above the deck and could not be easily moved to facilitate cleaning.
- Item 36Deck 4 - Beverage Storage - Galley Entrance
Refrigerators were installed along the bulkhead near the galley entrance on both the port and starboard sides. These units did not have adequate lighting and did not allow for proper cleaning behind or between them. The deck and bulkhead surfaces beneath and behind the units were soiled. The refrigerators were mounted on metal posts approximately five inches above the deck and could not be easily moved to facilitate cleaning.
Pools, hot tubs and water play areas3 findings
- Item 09Deck 5 Pool
This facility is currently being operated as a pool; however, the presence of water jet spray features throughout the pool designates it as an interactive recreational water facility. The bather load calculation is based on a turnover rate of 2.13 hours, whereas an interactive recreational water facility is required to maintain a maximum turnover rate of 2 hours. The technician stated that the required chlorine concentration range is 1–5 ppm. At the time of inspection, the chlorine concentration measured 1.38 ppm.
- Item 10Deck 5 Pool
This facility is currently being operated as a pool; however, the presence of water jet spray features throughout the pool designates it as an interactive recreational water facility. The bather load calculation is based on a turnover rate of 2.13 hours, whereas an interactive recreational water facility is required to maintain a maximum turnover rate of 2 hours. The technician stated that the required chlorine concentration range is 1–5 ppm. At the time of inspection, the chlorine concentration measured 1.38 ppm. The facility is equipped with a UV disinfection system. Additionally, the maintenance logs did not document when the filter housing and/or hair and lint strainer were cleaned, with the exception of the 14 December 2025 entry. The 01 December 2025 log was missing. The records available for review included entries dated 30 November and 14 December 2025.
- Item 44Deck 5 Pool
This facility is currently being operated as a pool; however, the presence of water jet spray features throughout the pool designates it as an interactive recreational water facility. The bather load calculation is based on a turnover rate of 2.13 hours, whereas an interactive recreational water facility is required to maintain a maximum turnover rate of 2 hours. The technician stated that the required chlorine concentration range is 1–5 ppm. At the time of inspection, the chlorine concentration measured 1.38 ppm. The facility is equipped with a UV disinfection system. Additionally, the maintenance logs did not document when the filter housing and/or hair and lint strainer were cleaned, with the exception of the 14 December 2025 entry. The 01 December 2025 log was missing. The records available for review included entries dated 30 November and 14 December 2025.
Bars1 finding
- Item 21Deck 5 - Club Bar
The stone countertops along the cold wells and back counter were in poor condition.
Buffets5 findings
- Item *Deck - 9 Colonnade
Passengers were not instructed to wash their hands at the handwashing station as they entered the buffet. The handwashing station is tucked behind the entrance bulkhead and not easily noticeable.
- Item 16Deck - 9 Colonnade
The poached egg station did not include a consumer advisory for smoked salmon that is offered for service.
- Item 19Deck - 9 Colonnade - Cold Island
Food items were stored beneath an approximate one inch gap between horizontal sneeze guard panels that did not adequately protect the food below. Additionally, a bowl of pickled fish was not adequately placed under the sneeze guard. These were corrected.
- Item 28Deck 3
Silverware dispensing containers were not angled appropriately to protect the mouthing ends.
- Item 39Deck - 9 Colonnade
One fruit fly was near the juice station.
Drinking water5 findings
- Item 03Production and Bunkering Halogenation
The halogen residual measured below 2.0 ppm (approximately 1.5 ppm) on 28 November 2025 during production for approximately one hour (1600–1700). The analyzer chart did not include any notation explaining the low halogen residual. Additionally, the halogen residual measured below 2.0 ppm (approximately 1.9 ppm) on 3 December 2025 during production for approximately 45 minutes (0000–0045). The inspector confirmed that the low-level alarm had been set at 1.9 ppm during production and bunkering, which would notify the crew only after the halogen residual had fallen below the required range. The crew immediately adjusted the low-level alarm set point.
- Item 06Legionella
The legionella sampling during October 2025 did not include a selection from the following locations: water heater, galleys, salon and pedicure devices, technical water sources with a risk of exposure via aerosolization to crew or passengers, such as deck washing, and misting features as required by the 2025 VSP Environmental Public Health Standards.
- Item 07Disinfection Records
Disinfection of the potable water system after maintenance consistently used the emergency procedure, even when the maintenance was planned or completed on a back-up system that was not in operation.
- Item 08Bunkering
The analyzer chart for the bunkering operation was not accurate. Approximately 20 minutes after the start of bunkering, the chart installed in the chart recorder was dated 14 November 2025 and displayed a heavy ink trace below 0.5 ppm. The crew replaced the chart at that time.
- Item 08Cross-Connection Control Log
A non-testable backflow prevention device located in the incinerator room on the hot water supply line to the garbage silo did not have an inspection date or documentation affixed to the device. The inspector confirmed that this device has since been removed.
Pantries2 findings
- Item 19Deck 7 - Coffee Bar
The ice scoop handle was in contact with ice inside the ice machine bin.
- Item 32Deck 5 - Club Bar
Two hard boiled shell eggs were inside the trash receptacle for the handwashing sink. The area was not in operation.
Medical center1 finding
- Item 02Acute Gastroenteritis (AGE) Surveillance Log
The AGE surveillance log did not include a separate column for 'comments and notes.' Additionally, the fever temperature was blank for three guests during the 18 November 2025 to 1 December 2025 voyage and the reason was not documented in the notes column. (VSP 2025 Environmental Public Health Standards)
Ventilation1 finding
- Item 43Air Handling Unit 03.5.1
The evaporator condenser was soiled with brown residue and the inside of the air handling unit had black residue near the evaporator condenser. This unit was scheduled for cleaning the day after the inspection.