Royal Caribbean International · CDC inspection record
Anthem of the Seas CDC inspection score
Latest score, full inspection history and the violations CDC inspectors found on Anthem of the Seas.
Source: CDC public records
Data checked on October 31, 2026
Pass mark: 86 out of 100
Independent site, not the CDC
Royal Caribbean InternationalInspected June 11, 2026
100out of 100
Latest CDC sanitation score
Passed
Anthem of the Seas scored 100 out of 100 in its latest CDC Vessel Sanitation Program inspection, on June 11, 2026. It passed: ships pass with 86 or more.
+1 vs previous inspection (99, May 16, 2025)
97.6average of the last 5 inspections
86lowest score (June 2016)
12inspections since 2016
0failed inspections
Inspection history of Anthem of the Seas
Every CDC inspection score on record for Anthem of the Seas: 12 inspections from February 25, 2016 to June 11, 2026, 2 perfect scores of 100 and no failed inspections.
The full findings of the last 3 inspections, as written in the CDC reports. Each finding refers to an item of the CDC’s Vessel Sanitation Program standards; points are deducted by item, for a single significant violation or for a pattern of similar ones (CDC FAQ).
June 11, 2026
100Passed
23 findings · 0 points deducted
No points deducted.
All 23 findings the inspectors wrote down, grouped by area of the ship. Findings with a red edge belong to an item that lost points; the others were noted without a deduction.
Galleys (kitchens)16 findings
Item 08Deck 2 - Backflow Prevention Devices
The atmospheric vent for one of the combination ovens was angled upward. Additionally, the piping connected to the backflow vent inside the ventilation hood cleaning locker was on a slight incline which prevented proper draining. This was corrected immediately.
Item 20Deck 4 - Starboard Ice Machine
The tip of the metal ice scoop was cracked creating a difficult to clean surface.
Item 20Deck 4 - Bakery
The dispensing end of the stainless steel metered water hook was bent which created a difficult-to-clean surface. Apparent flour debris was observed in this area.
Item 21Deck 4 - Cafe Promenade
A ledge was at the countertop slab juncture to the right of the coffee dispensers.
Item 22Deck 3 - Dishwash
The internal curtains separating the wash tank from the final rinse compartment in the port side glasswash machine were curled and created openings between the two compartments.
Item 22Deck 3 - Dishwash
The starboard side glasswash has been out of order for approximately one month. Staff stated parts are on order.
Item 22Deck 3 - Potwash
The final sanitizing rinse compartment of the three-compartment sink would not retain water. Staff stated they were putting all the soiled pots and pans in the potwash machine until it was repaired. Staff reported this issue began the morning of the inspection.
Item 22Deck 4 - Dishwash
The port side glasswash machine had been out of order for the past month. Crew stated parts are on order.
Item 22Deck 4 - Dishwash
The soiled side entry curtains of the flight-type dishwashing machine were curled and stiff.
Item 26Deck 4 - Bakery
Flour debris was inside the dispensing end of the stainless steel metered water hook that was bent, which created hard to clean surfaces.
Item 26Deck 4 - Bakery
More than a day's accumulation of brown food residue coated a fastener on the mixing head of the in-use deck mounted mixer that was closest to the hot galley.
Item 27Deck 4 - Starboard Ice Machine
Sticky brown food residue was on the internal surface of the right ice bin lid.
Item 33Deck 4 - Starboard Hot Galley
Deck tile grout was recessed or pitted in multiple locations throughout this section of the galley. This was most evident around scupper drains and steel platforms.
Item 33Deck 14 - Windjammer
An open seam was at the profile strip connected to the bulkhead behind the middle braising pan.
Item 33Deck 3
Deck tile grout was recessed or pitted in multiple locations throughout this section of the galley. This was most evident around scupper drains and steel platforms.
Item 36Deck 15 - Solarium
The light intensity measured less than 220 lux at the braising pan and the deep fat fryers. This was corrected before the end of the inspection.
Buffets4 findings
Item 21Deck 14 - Windjammer
The sealant around multiple countertop hot plates and cold wells were missing at multiple buffet stations. Corrective actions started after the breakfast service.
Item 21Deck 14 - Pastry Starboard Side
The countertop had a chip on the employee side where the countertop meets the stainless steel back splash. This was corrected before the end of the inspection.
Item 27Deck 14 - Pastry Starboard Side
The countertop had food debris inside a chip on the employee side where the countertop meets the stainless steel back splash. This was corrected before the end of the inspection.
Item 33Deck 15 - Solarium Beverage Station
An open penetration was on the bulkhead in the technical space below the ice/water dispenser.
Bars2 findings
Item 27Deck 4 - Wine Pantry
Water pooled on the bottom of the technical compartment from the water filter connection for the counter-mounted espresso machine that was consistently leaking.
Item 34Deck 4 - Wine Pantry
Water was consistently leaking from the water filter connection for the counter-mounted espresso machine and pooling on the bottom of the technical compartment.
Pest control1 finding
Item 40ActiveSurveillance Pest Monitoring Log
No follow-up was conducted for a live fruit fly sighting on deck 2 near the incinerator after 30 May 2026.
All 31 findings the inspectors wrote down, grouped by area of the ship. Findings with a red edge belong to an item that lost points; the others were noted without a deduction.
Galleys (kitchens)12 findings
Item 16Deck 4 - Pantry Walk-In Refrigeration Unit
Six cartons of liquid eggs measured between 60.1°F and 72.3°F with a calibrated thermometer. All other potentially hazardous food items inside the walk-in refrigeration unit measured 41°F and below. Crew initiated corrective action.
Item 17Deck 4 - Café Promenade
A tray of tomato and mozzarella sandwiches, identified with a time control label, was stored inside a reach-in refrigeration unit that was not designated as a time control unit. Crew initiated corrective action.
Item 18Deck 4 - Pantry Walk-In Refrigeration Unit
A tray of cold-smoked salmon was stored on a shelf above a bin of ready-to-eat bagels. Crew initiated corrective action.
Item 20Deck 14 - Coastal Kitchen Dishwashing Area
A cutting board stored on the clean rack was heavily scored. Brown residue collected inside areas of recess. Crew initiated corrective action.
Item 21Deck 4 - Sorrento's
The top corners of time control trolleys 2A and 2B were heavily damaged and chipped, creating difficult-to-clean surfaces.
Item 22Deck 14 - Windjammer Potwashing Area
The 'low temperature' alarm light on the front-loading potwashing machine was covered with sealant, obstructing sight during periods of inadequate temperature.
Item 22Deck 14 - Coastal Kitchen Dishwashing Area
The plastic housing on the two upper wash and final rinse arms was broken and chipped inside the double-rack hood-type dishwashing machine. Additionally, two wash nozzles were soiled with debris, creating an ineffective spray pattern. Crew initiated corrective action.
Item 22Deck 5 - Jamie's Italian
Two upper wash arms in the double rack hood-type dishwashing machine were loose. Additionally, three wash/final rinse nozzles were blocked with debris, preventing an effective spray pattern. Crew initiated corrective action.
Item 22Deck 4 - Sorrento's Potwashing Area
Soiled food equipment was racked in a manner that prevented exposure to an unobstructed spray inside the hood-type potwashing machine. A small, plastic bin was racked beneath a larger plastic bin, preventing the spray from reaching all surfaces of the larger bin. Crew initiated corrective action.
Item 26Deck 15 - SeaPlex Doghouse Show Galley
Food-contact surfaces of the hot dog rollers were soiled with a small amount of grease. This area was not in service.
Item 26Deck 14 - Coastal Kitchen Dishwashing Area
Brown residue accumulated inside recessed areas of a heavily scored cutting board. Crew initiated corrective action.
Item 27Deck 14 - Windjammer Hot Galley
The top of the soap dispenser, located at the handwashing station between the combination ovens, was soiled with water drip from the combination oven's backflow prevention device vent. The vent's drain was directed towards the soap dispenser.
Dining rooms7 findings
Item 08Deck 15 - SeaPlex Doghouse Beverage Station
A plastic hose was attached to the atmospheric vent of the carbonator backflow prevention device for the deck mounted soda multi flow machine in a manner that prevented draining. Water collected inside this hose. Crew initiated corrective action.
Item 20Deck 15 - SeaPlex Doghouse Beverage Station
The deck-mounted soda multi-flow machine was out of service for at least 2 months while awaiting repair. Crew identified a technician was onboard to repair the unit.
Item 20Deck 14 - Johnny Rockets Beverage Station
The white piece of plastic surrounding the gray ice chute for the counter-mounted ice bin was in disrepair, creating a difficult to clean surface. Black and brown residue accumulated inside the food splash zone surrounding the top of the ice bin. Crew initiated corrective action.
Item 26Deck 15 - SeaPlex Doghouse Beverage Station
The deck-mounted soda multi flow machine was out of service for over 2 months but was excessively soiled with sugar and sticky residue on the food contact surfaces of the dispensing nozzle. Crew initiated corrective action.
Item 26Deck 14 - Johnny Rockets Beverage Station
Black and brown debris soiled the food splash zone surrounding the top of the counter-mounted ice bin. Crew initiated corrective action.
Item 27Deck 15 - SeaPlex Doghouse Beverage Station
The deck-mounted soda multi flow machine was out of service for at least 2 months but was excessively soiled on multiple nonfood-contact surfaces. Excessive crystallized sugar and sticky residue accumulated inside the technical compartment, on the outside of the machine, in the drip tray, and under the machine. Additionally, the bottom of the machine was covered in sticky debris. The excess sugary residue was so thick that it slowed the opening of the carbonator drawer. Crew initiated corrective action.
Item 33Deck 15 - SeaPlex Doghouse Beverage Station
Brown syrup dripped down the mount of the out-of-service, deck-mounted soda multi-flow machine and collected on the deck. Crew initiated corrective action.
A plastic hose was attached to the atmospheric vent of the carbonator backflow prevention device for the deck mounted soda multi flow machine in a manner that prevented draining. Water collected inside this hose. Crew initiated corrective action.
Item 16Deck 14 - Windjammer Hot Line
Time/temperature control for safety (TCS) cooked rice, dal, bean stew, pasta, and Alfredo sauce were out for service in a time control unit; however, were not identified with a 4-hour discard label. The service period was greater than 4 hours. Crew initiated corrective action.
Three flies flew in front of the deck-mounted soda multi-flow system.
Room service3 findings
Item 16Deck 9 - Walk-In Refrigeration Unit
Crew could not confirm that three hotel pans of chicken wings reached the full-cook temperature of 165°F. Crew confirmed these chicken wings were cooked to approximately 161°F through logs and discussion. Crew identified these wings were cooled and placed into cold holding prior to completing cooking immediately before service. Crew initiated corrective action.
Item 18Deck 9 - Walk-In Refrigeration Unit
Three hotel pans of partially cooked chicken wings were stored above raw salmon filets and raw ground beef patties. Crew confirmed these chicken wings were cooked to approximately 161°F through cooking logs and discussion but could not confirm they reached the full-cook temperature of 165°F. Raw salmon and raw ground beef patties require a lower cooking temperature for microorganism destruction. Crew initiated corrective action.
Item 30Deck 9 - Crew Toilets
The handwashing soap did not lather effectively for hand washing. Crew initiated corrective action.
Bars2 findings
Item 39Deck 6
One fruit fly was in this area.
Item 40Deck 14 - Sky Bar
There were no effective barriers to protect the interior of the pantry from potential pest entry between the open deck of the bar and the corridor. Crew identified the fire door between the pantry and the open corridor remained open during service.
There was no effective air gap or backflow prevention device provided for the potable water filling line for the chemical tank. Crew initiated corrective action.
Pools, hot tubs and water play areas1 finding
Item 10Deck 14 - Outdoor Swimming Pool # 1
The bottom left screw was missing for the swimming pool’s portside antientrapment drain cover.
March 3, 2024
98Passed
39 findings · 2 points deducted
Points deducted (100 − 2 = 98):
−1 ptItem 21: Nonfood-contact surfaces designed, constructed, maintained, installed, located
All 39 findings the inspectors wrote down, grouped by area of the ship. Findings with a red edge belong to an item that lost points; the others were noted without a deduction.
Galleys (kitchens)18 findings
Item 20Deck 2 - Dishwash
A previously cleaned and sanitized food service container had rough areas and a large gouge in the food-contact surface. This was removed and discarded.
Item 20Deck 4 - Starboard Beverage Station
The food-contact end of the metal ice scoop inside the ice machine was bent making the area difficult to clean.
Item 20Deck 4 - Pastry
Three circular penetrations were on the underside of the mixing head of the small right deck mounted mixer. Food soil was inside one of the penetrations. The unit was previously cleaned and sanitized.
Item 20Deck 5 - Chops Grille
The induction generator was out of service since 12 April 2023 due to electrical failure. A work order was placed. Estimated arrival for spare parts is 19 March 2024.
Item 21Deck 14 - Windjammer Hot Galley
The handle for the salamander oven was constructed of a wood-like material that was absorbent and not smooth.
Item 21Deck 4 - Tournanp Station
Water was leaking from the underside of the technical compartment for two tilting kettles and dripping onto the deck below. Staff stated this was from poor insulation on a steam line inside the compartment.
Item 21Deck 3 - Roast Station
A hot holding cabinet in active use was dripping grease from the lower edge of the door onto the cabinet and deck below. It appeared the door gasket was in poor condition.
Item 21Deck 14 - Windjammer Hot Galley
On the back side of the counter across from the combination ovens, the coving grout along the deck to equipment juncture was loose and able to be removed.
Item 22Deck 14 - Windjammer Dishwash
At the clean end the conveyor dishwash machine, a far-right upper final sanitizing rinse spray nozzle was producing an intermittent spray. Water pressure varied from full pressure to minimal pressure when the machine was in operation. Removing the spray arm, cleaning out the nozzle, and increasing the water pressure did not correct the issue. The technician replaced the nozzle which corrected the issue.
Item 26Deck 4 - Pastry
Three circular penetrations were on the underside of the mixing head of the small right deck mounted mixer. Food soil was inside one of the penetrations. The unit was previously cleaned and sanitized.
Item 27Deck 5 - Jamie's Italian
Grease residue was on the underside of the counter-mounted combination oven technical box.
Item 27Deck 3 - Roast Station
A hot holding cabinet in active use was dripping grease from the lower edge of the door onto the cabinet and deck below. It appeared the door gasket was in poor condition.
Item 27Deck 5 - Chops Grille
Grease residue was on the underside of the counter-mounted combination oven technical box.
Item 33Deck 3 - Roast Station
A hot holding cabinet in active use was dripping grease from the lower edge of the door onto the cabinet and deck below. It appeared the door gasket was in poor condition.
Item 33Deck 14 - Windjammer Hot Galley
The tile grout was recessed and missing around the deck sinks.
Item 33Deck 4 - Tournanp Station
Water was leaking from the underside of the technical compartment for two tilting kettles and dripping onto the deck below. Staff stated this was from poor insulation on a steam line inside the compartment.
Item 36Deck 4 - Pastry
Light intensity did not reach 110 lux of light between the upright freezer and ice cream machine.
Item 39Deck 5 - Chops Grille / Wonderland / Izumi
A large house fly was in the warewash clean storage area. The area was in operation.
Buffets10 findings
Item 21Deck 14 - Windjammer Coffee and Juice Outlet
The cord for the juice machine was laying on the counter. The machine was not portable.
Item 21Deck 14 - Windjammer Island #5 (Cereal Station)
Starting at the handwash station and moving left, the underside of the countertop was rough and difficult to clean above technical compartment #5.
Item 24Deck 14 - Windjammer Coffee/Bakery Outlet
The white bucket of sanitizing solution measured less than 50 ppm concentration for chlorine.
Item 26Deck 2 - Beverage Station - Ice Machine
Brown residue of more than a day's accumulation was under and around a black fastener along the back metal panel below the ice dispenser. The unit was previously cleaned and sanitized.
Item 26Deck 2 - Beverage Station
A coffee mug stored on the buffet for crew self-service had food debris on the inside surface. This was sent back to be re-cleaned and sanitized.
Item 27Deck 14 - Windjammer Coffee/Bakery Outlet
The back counter shelves storing energy drinks were soiled with more than one day's accumulation of dust. The area was in operation during the inspection.
Item 28Deck 2 - Utensil Storage
Utensil storage containers positioned throughout the self-service food stations were positioned in a manner that did not protect the mouthing ends of the stored utensils. The stainless utensil holders were positioned only a few feet off the deck and the silverware was installed vertical and not angled to protect against potential contamination from crew members who can stand directly above.
Item 30Deck 14 - Solarium Bistro
The portside passenger entrance handwash station was placed out of service on the night before the inspection.
Item 33Deck 2 - European Line
Dust of more than a day's accumulation was between deckhead paneling above the counter-mounted microwave.
Item 36Deck 14 - Windjammer Show Galley
The light intensity measured less than 220 lux to the left and right of the shawarma machine, and less than 110 lux behind this machine.
Food safety, general2 findings
Item 20Bars - Soda Guns
Slotted fasteners were on the food splash area of all soda guns. Staff explained nonslotted screws were to be delivered by 31 March.
Item 33Deck Grouting - Main Galleys
Deck tile grouting was missing or recessed throughout much of the hot lines in both Main Galleys on Deck 3 and 4.
Food preparation rooms2 findings
Item 33Deck 2 - Commissary
Deck tile grouting in front of the two potato peeling machines was missing or recessed in this area.
Item 36Deck 2 - Commissary
Light intensity in the center of the two potato peeling machines and in back of the machines did not reach 220 lux and 110 lux of light respectively.
Medical center2 findings
Item 02Immediate Contact Interviews
The 48-hour verbal interview of an asymptomatic cabin mate for an AGE case during voyage 33388 was not recorded in the electronic medical database.
Item 11Late Report
During voyage 33388 (2/17-2/25/2024), a food worker who experienced acute gastroenteritis symptoms on 2/18 at 0600 did not report to medical until 0937 later that day. Timecard records indicated this individual worked and dined in the crew mess during this period. A food assessment and disciplinary action were taken.
Drinking water2 findings
Item 08Piping Identification
Potable water lines in the engine room for the handwash sinks and eye washing stations, and in the garbage room for the handwash stations were not striped blue or blue/green/blue in accordance with ISO 14726
Item 08Cross-Connection Control Log
The cross-connection control log did not list an atmospheric vacuum breaker (AVB) for the bucket fill station in the garbage room.
Housekeeping1 finding
Item 41Women's Restroom Near Conference Room
The women's public restroom did not have a sign or pictogram advising users to use a paper towel or tissue to open the door. Additionally, the exit was not hands free.
Pantries1 finding
Item 26Deck 14 - Pool Bar
Inside the ice machine near the 'outside bar,' a small amount of pink residue was on the inside of the ice deflector panel,
Pools, hot tubs and water play areas1 finding
Item 10Deck 14 - Current Pool
The manual comparison test for halogen concentration conducted in the pool machinery room read 2.48 ppm on the inspectors photometer and 2.50 ppm on the crews photometer; however, the analyzer halogen concentration reading was 3.43 ppm presenting a differential amount at 0.93 - 0.95 ppm. The analyzer was re-calibrated during the inspection.
To see this report on the CDC site: open the CDC inspection search, choose Anthem of the Seas in the list of cruise ships, select “All Dates” and press Search, then open “Report” next to the inspection date. (The CDC tool does not allow direct links to a single report.)