April 29, 2026
98Passed49 findings · 2 points deducted
Points deducted (100 − 2 = 98):
- −2 ptsItem 22: Dishwashing / equipment washing facilities designed, constructed, maintained, installed, located, operated, TMDs, test kits
All 49 findings the inspectors wrote down, grouped by area of the ship. Findings with a red edge belong to an item that lost points; the others were noted without a deduction.
Galleys (kitchens)32 findings
- Item 16Deck 5 - Walk-In Refrigeration Unit # 5411
One, open cardboard container of soy milk was not labeled with a 7-day discard label. Crew could not identify when the container of milk was opened. Crew initiated corrective action.
- Item 17Deck 5 - Pantry
No time control plan was physically posted inside the pantry area located off of the main galley. The nearest posted plan that included the set up and discard times for the pantry's rolling fridge #339, which was physically identified as a time control, was in the main preparation area on the opposite side of the galley. Crew initiated corrective action.
- Item 19Deck 4 - Bakery
A plastic rolling container of pumpernickel bread crumbs, removed from its original container, was not identified with the common name of the item. Crew initiated corrective action.
- Item 19Deck 5 - Walk-In Freezer Unit # 5411
A layer of ice accumulated directly on corn stored inside a plastic container on the top shelf of the unit. The plastic lid was ajar, causing cold air to freeze directly on the corn. Crew initiated corrective action.
- Item 19Deck 2 - Dry Storage Area
Three plastic rolling containers of flour, removed from their original containers, were not identified with the common name of the item. Crew initiated corrective action.
- Item 20Deck 3 - Forward Beverage Station
There were two tears in the food splash surface of the front panel for the deck mounted ice machine, creating two difficult to clean, rough surfaces. Brown and orange residue accumulated around these two difficult to clean surfaces.
- Item 20Deck 4 - Bakery
The left and right edges of the in-use dough sheeter belt were frayed, with numerous difficult-to-clean stringy edges.
- Item 20Deck 15 - Mason Jar
The walk-in refrigerator did not have an internal temperature measuring device inside of the unit. This was corrected immediately.
- Item 21Deck 5 - Forward Entrance
The edges of three mobile, stainless-steel trolleys were dented and damaged, creating sharp difficult-to-clean surfaces. Brown and silver residue flaked from the damaged surfaces.
- Item 22Deck 5 - Portside Warewashing Area
Steam exited from the side and bottom gaps created from undersized curtains installed on the soiled end of the conveyor type warewashing machine. Steam from the machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam. The curtains were replaced with larger curtains the extended over the entire soiled opening of the machine.
- Item 22Deck 5 - Portside Warewashing Area
One plastic container with 25 soiled glasses was stored directly on the deck underneath the wash compartment of conveyor-type warewashing machine. Crew were actively conducting warewashing operations. Crew initiated corrective action.
- Item 22Deck 5 - Potwashing Area
Water spewed from the bottom right side of the front door for the potwashing machine and pooled on the deck below.
- Item 22Deck 4 - Warewashing Area
Steam exited from the side and bottom gaps created from undersized curtains installed on the soiled end of the portside conveyor type warewashing machine. Steam from the machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam. The curtains were replaced with larger curtains the extended over the entire soiled opening of the machine.
- Item 22Deck 16 - Windjammer
The wash compartment of the flight-type warewashing machine was spraying into the final sanitizing rinse compartment as plates were being sanitized. This was corrected immediately.
- Item 22Deck 16 - Windjammer
Two final sanitizing rinse nozzles to the glasswash rack type machine did not have a fan like spray pattern.
- Item 22Deck 2 - Scullery
Water steadily spewed from the soiled end of the conveyor type warewashing machine and dripped from the soiled landing onto the deck below. The first set of spray arms was misaligned, causing water to spray towards the entrance of the machine.
- Item 26Deck 3 - Forward Beverage Station
There were two tears in the food splash surface of the front panel for the deck mounted ice machine, creating two difficult to clean, rough surfaces. Brown and orange residue accumulated around these two difficult to clean surfaces.
- Item 27Deck 5 - Forward Entrance
The edges of three mobile, stainless-steel trolleys were dented and damaged, creating sharp difficult-to-clean surfaces. Brown and silver residue flaked from the damaged surfaces.
- Item 27Deck 17 - Coastal Kitchen - Side Station
A clean storage rack with previously cleaned and sanitized utensils was soiled with a strand of human hair. The venue was not in operation at the time of the inspection. This was corrected immediately.
- Item 28Deck 17 - Coastal Kitchen - Side Station
Previously cleaned and sanitized utensils were stored on a clean storage rack soiled with a strand of human hair. The venue was not in operation at the time of the inspection. This was corrected immediately.
- Item 33Deck 8 - 115 Central Park
The deckhead light fixture above the preparation station had an accumulation of water. This was corrected immediately.
- Item 33Deck 4 - Warewashing Area
Steam from the conveyor-type warewashing machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam. The curtains were replaced with larger curtains the extended over the entire soiled opening of the machine.
- Item 33Deck 5 - Portside Warewashing Area
One plastic container with 25 soiled glasses was stored directly on the deck underneath the wash compartment of conveyor-type warewashing machine. Crew were actively conducting warewashing operations. Crew initiated corrective action.
- Item 33Deck 5 - Portside Warewashing Area
Steam from the conveyor-type warewashing machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam.
- Item 33Deck 16 - Windjammer
A removable rug at the starboard side entrance of the galley had an accumulation of water. Additionally, the deck underneath the rug was unfinished.
- Item 33Deck 2 - Hot Preparation Area
Water pooled on the deck underneath the utility sink’s cold-water supply pipe that was in disrepair.
- Item 34Deck 2 - Hot Preparation Area
Water steadily leaked from the cold-water supply pipe for the utility sink located next to the preparation counter and pooled on the deck underneath.
- Item 35Deck 2 - Scullery
Water pooled on the deck below the soiled end of the conveyor type warewashing machine. The first set of spray arms was misaligned, causing water to spray towards entrance of the machine.
- Item 35Deck 5 - Potwashing Area
Water spewed from the bottom right side of the front door for the potwashing machine and pooled on the deck below.
- Item 36Deck 17 - Coastal Kitchen
The light intensity along the external side of the reach-in refrigerators measured less than 220 lux. This was corrected prior to the end of the inspection.
- Item 37Deck 4 - Warewashing Area
Steam exited from the side and bottom gaps created from undersized curtains installed on the soiled end of the portside conveyor type warewashing machine. Steam from the machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam. The curtains were replaced with larger curtains the extended over the entire soiled opening of the machine.
- Item 37Deck 5 - Portside Warewashing Area
Steam exited from the side and bottom gaps created from undersized curtains installed on the soiled end of the conveyor type warewashing machine. Steam from the machine collected on the deckhead outside of the ventilation hood and dripped back onto the machine and deck below. The ventilation unit was extracting; however, it was insufficient to control the large volume of steam.
Bars2 findings
- Item 22Deck 15 - Lime and Coconut Bar - Port Side
The hood-type warewashing machine had been out of order as of 28 April 2026.
- Item 24Deck 15 - Lime and Coconut Bar - Starboard Side
The chlorine solution in the sanitizing bucket measured 25 ppm. This was corrected immediately.
Buffets5 findings
- Item 21Deck 17 - Suite Lounge
Several cords from the counter-mounted coffee machine were resting on the countertop. Additionally, the countertop surface around the cords was soiled with an accumulation of debris greater than a day's worth. The venue was not in operation at the time of inspection. This was corrected immediately.
- Item 21Deck 15 - Crown Lounge
The counter mounted coffee machine’s front left leg mount was not adequately sealed to the countertop exposing an open seam.
- Item 21Deck 15 - Solarium Bistro - Gluten Free Station
The countertop had an open seam on the right corner underneath the sneeze guard. This was corrected immediately.
- Item 27Deck 17 - Suite Lounge
The countertop surface around the counter-mounted coffee machine cords was soiled with an accumulation of debris greater than a day's worth. The venue was not in operation at the time of inspection. This was corrected immediately.
- Item 36Deck 16 - Windjammer - Pastry Station
The light bulb shield around the hanging deckhead light fixture over the serving line was shattered. This venue was in operation at the time of the inspection. No food was impacted.
Drinking water5 findings
- Item 05Deck 14 - Distant Point
The manually measured free chlorine residual level was greater than 0.2 mg/L (ppm) from the halogen analyzer’s measurement. Calibration was conducted immediately.
- Item 06Legionella Potable Water Sampling Plan
A Legionella sample from neither of the two potable water heaters was included in the previous six-month sampling plan as per the VSP 2025 Environmental Public Health Standards.
- Item 08Reverse Osmosis Units #3 and #4
The permeate water lines directed to the potable water system were not striped blue/gray/blue as they exited the reverse osmosis units.
- Item 08Bunker Line Dosing Station
The backflow prevention devices for the eye wash sink, and the deck cleaning hose were in disrepair with blocked atmospheric vents.
- Item 08Pipe Disinfection Log
On 25 April 2026, during a pipe disinfection process, the specific free chlorine residual value was not listed in the log after flushing as per the VSP 2025 Environmental Public Health Standards.
Medical center2 findings
- Item 11Acute Gastroenteritis (AGE) Log
A food employee had symptom onset at 0800 on 16 February 2026 and did not report to medical until 17 February 2026 at 0058. The food employee went to work and to the crew mess after their symptom onset and before they reported to medical. A food risk assessment was completed. Corrective actions were taken.
- Item 11Acute Gastroenteritis (AGE) Log
A food employee had symptom onset at 2300 on 16 February 2026 and did not report to medical until 17 February 2026 at 0724. The food employee went to work before reporting to medical. A food risk assessment was completed. Corrective actions were taken.
Dining rooms1 finding
- Item 33Deck 4 - Izumi Teppanyaki
The edges of the swinging doors to the crew area of the two teppanyaki grills were in disrepair, with rough surfaces exposing the difficult-to-clean wood underneath.
Food safety, general1 finding
- Item 39Integrated Pest Management
Flies were in the following food areas: - Deck 17 - Suite Lounge - One fly was over the handwashing station. - Deck 2 - Crew Mess - Two flies were around the buffet beverage station.
Pools, hot tubs and water play areas1 finding
- Item 10All Pools
The safety lines on the flotation devices were not easily accessible, preventing the devices from being used as designed.